 CTE8000 / CTU8000 Series
OEM pressure transmitters for industrial media
FEATURES * 0...-1 to 0...100 bar, 0...-15 to 0...1500 psi gage1 or absolute10 * For many industrial gases and liquids * 0...10 V, 0.5...4.5 V, 0...5 V, 1...6 V or 4...20 mA output * Field interchangeable * For industrial use MEDIA COMPATIBILITY
Wetted materials: stainless steel 1.4404 (316L), ceramic AL2O3, NBR9 Housing: stainless steel,protection class IP 64 (according to DIN EN 60529) respectively NEMA 4X1
SPECIFICATIONS11,12
Maximum ratings Supply voltage (reverse polarity protection) 12...30 V CTx8...0 9...30 V CTx8...1, ...6, ...7 9...30 V CTx8...42 Maximum load current (source) CTx8...0, ...1, ...6, ...7 Temperature limits Storage Operating8 Compensated Humidity limits Vibration (5 to 500 Hz) Mechanical shock Proof pressure
3
ELECTRICAL CONNECTION
0...10 V, 0.5...4.5 V, 0...5 V, 1...6 V output
+Vs 1 Vout 2 -Vs 4 case 3
V
12 (9) to 30 V
sensor
1 mA
GND
-55 to 100C -40 to 100C 0 to 70C 0 - 98 %RH 10 gRMS 50 g 2 x rated pressure
4...20 mA output
+Vs 1 N/C 2 -Vs 4 case 3 9 to 30 V
sensor
V
RL GND
December 2008 / 508
1/6
www.sensortechnics.com
CTE8000 / CTU8000 Series
OEM pressure transmitters for industrial media
COMMON PERFORMANCE CHARACTERISTICS
Characteristics
Operating pressure CTE8001... CTE8N01... CTE8P01... CTE8002... CTE8005... CTE8010... CTE8016... CTE8020... CTE8025... CTE8035... CTE8050... CTE8070... CTE8100... CTU8015... CTU8N15... CTU8P15... CTU8030... CTU8100... CTU8200... CTU8300... CTU8500... CTU8700... CTU81K0... CTU81K5... Offset Span Offset Span
Min.
0 -1 -1 0 0 0 0 0 0 0 0 0 0 0 -15 -15 0 0 0 0 0 0 0 0
Typ.
Max.
1 +1 0 2 5 10 16 20 25 35 50 70 100 15 +15 0 30 100 200 300 500 700 1000 1500
Unit
bar
p si
Thermal effectss (0 to 70C)4 Thermal effects (-40 to 0C, 70 to 100C)
0.02 0.02 0.03 0.03 0.1 0.3 0.04 1
0.05 0.05
%FSO/C
Non-linearity, hysteresis (BSL) and repeatability5 Long term stability6 Output noise (0 < f < 1 kHz) Response time (10 to 90 %) Power supply rejection Offset Span CTx8...4 all others CTx8...4 all others
0.3 %FSO
5
ms
0.05 0.002 0.08 0.002 %FSO/V
December 2008 / 508
2/6
www.sensortechnics.com
CTE8000 / CTU8000 Series
OEM pressure transmitters for industrial media
INDIVIDUAL PERFORMANCE CHARACTERISTICS
0...10 V output (VS = 15 V, RL > 100 k, tamb = 25C)
Characteristics
Zero pressure offset Full scale span
7
Min.
CT...8N... all others CT...8N... all others 4.9 9.9 4.9
Typ.
5 0.03 5 10 3
Max.
5.1 0.1 5.1 10.1 25 5
Unit
V
Output impedance Current consumption (no load)
mA
0.5...4.5 V output (VS = 15 V, RL > 100 k, tamb = 25C)
Characteristics
Zero pressure offset Full scale span7 Output impedance Current consumption (no load) CT...8N... all others CT...8N... all others
Min.
2.45 0.45 1.95 3.95
Typ.
2.5 0.5 2 4 3
Max.
2.55 0.55 2.05 4.05 25 5
Unit
V
mA
0...5 V output (VS = 15 V, RL > 100 k, tamb = 25C)
Characteristics
Zero pressure offset Full scale span7 Output impedance Current consumption (no load) CT...8N... all others CT...8N... all others
Min.
2.45 2.45 4.95
Typ.
2.5 0.03 2.5 5.0 3
Max.
2.55 0.08 2.55 5.05 25 5
Unit
V
mA
1...6 V output (VS = 15 V, RL > 100 k, tamb = 25C)
Characteristics
Zero pressure offset Full scale span
7
Min.
CT...8N... all others CT...8N... all others 3.45 0.95 2.45 4.95
Typ.
3.5 1 2.5 5.0 3
Max.
3.55 1.05 2.55 5.05 25 5
Unit
V
Output impedance Current consumption (no load)
mA
4...20 mA output (VS = 15 V, RL = 100 , tamb = 25C)
Characteristics
Zero pressure offset Full scale span
7
Min.
CT...8N... all others CT...8N... all others 11.9 3.9 7.9 15.9
Typ.
12.0 4.0 8.0 16.0 250
Max.
12.1 4.1 8.1 16.1
Unit
mA
Power consumption (IL = 20 mA)
December 2008 / 508
mW
3/6
www.sensortechnics.com
CTE8000 / CTU8000 Series
OEM pressure transmitters for industrial media
Specification notes:
1. IP 64 protection is given when the connector is locked. For proper function the gage port is vented to the atmosphere through the connector/cable assembly. Thus the cable end must have access to the ambient pressure. 2. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the load limitation diagram. 3. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. 4. Thermal effects tested and guaranteed from 0 to 70C relative to 25C. All specifications shown are relative to 25C. 5. Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span. 6. Long term stability is the change in output after one year or 1 million pressure cycles. 7. Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure. 8. Tests are in accordance with EN61000-6-2, April 1999. 9. Other material on special request. When using devices with optional nickel plated fittings, consider the media compatibility of the fittings also. 10. Available for pressure ranges from 1 bar (15 psi) absolute upwards only. 11. CE-labelling is in accordance with 89/336/EEC. 12. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC.
OUTLINE DRAWING
NOM 72 (2.83) 6.5 (0.26) 52 (2.05) 4 vent hole
21.8 (0.86) diam.
G 1/8" (BSP)
1 3
M12 x 1 connector
2
Detail A
Detail A
Output
4.0 (0.16) diam.
Pin 1 2 3 4 0...10 V 0.5...4.5 V 0...5 V, 1...6 V +VS Vout case -Vs 4...20 mA +VS NC case -Vs
o-ring grove for o-ring 11.8 x 1.8 (0.456 x 0.071) (ZA004029)
mass: 72 g
dimensions in mm (inches)
December 2008 / 508
4/6
www.sensortechnics.com
CTE8000 / CTU8000 Series
OEM pressure transmitters for industrial media
RECOMMENDED ACCESSORY (not included in delivery)
ZK000101: ZP000112-B: Connector/cable assembly (different cable lenghts available) Mating Connector (without cable)
NOM 2 m
(other cable lenghts on request)
PIN CONNECTION Pin Flying lead end Brown Green White and shield Yellow
NOM 60
Shield
1 2 3
36.5
4
Vent tube
M12x1 O 20
Note: For proper function of all gage devices the vent tube must have access to the ambient atmosphere.
dimensions in mm
OPTIONAL PRESSURE FITTINGS (brass, nickel plated)
Male fittings
A B C
LOAD LIMITATION
4...20 mA output version
1400 Ohm 1200
D
1000 800
op e ra ratin ng g e
600
Female fittings
E
G F H
400 200 0 5 9
16 20 25 30 V supply voltage
Dimensions in mm (inches) A 1/8" BSPT 1/4" BSPT 3/8" BSPT 1/2" BSPT 1/8" BSP 1/4" BSP 3/8" BSP 1/8" NPT 1/4" NPT B 8 (0.315) 12 (0.472) 11.5 (0.453) 16 (0.630) 12.5 (0.492) 8.5 (0.335) 12.5 (0.492) 10 (0.394) 14 (0.551) C 13 (0.512) 5.5 (0.217) 5 (0.197) 7 (0.276) 11 (0.433) 5 (0.197) 7 (0.276) 13 (0.512) 6 (0.236) D (Hex.) 14 (9/16") 14 (9/18") 17 (11/16") 22 (7/8") 14 (9/16") 19 (3/4") 22 (7/8") 17 (11/16") 22 (7/8")
E 1/8" BSP 1/4" BSP 3/8" BSP 1/2" BSP
Dimensions in mm (inches) F 5 (0.197) 7 (0.276) 6 (0.236) 18 (0.707) G 15 (0.591) 20 (0.787) 20 (0.787) 23 (0.906) H (Hex.) 14 (9/16") 17 (11/16") 22 (7/8") 24 (15/16")
December 2008 / 508
5/6
www.sensortechnics.com
CTE8000 / CTU8000 Series
OEM pressure transmitters for industrial media
ELECTROMAGNETIC CAPABILITY8
Test conditions Criterion Interference Radiated, radio frequency EN61000-4-3: Grade 3, 10 V/m, 80 to 1000 MHz A <1 %FSO electromagnetic field immunity (RFI) 80 % AMC (1 kHz) Electrical fast transient / EN61000-4-4: Grade 3, 2 kV B <1 %FSO burst immunity (EFT) Electrostatic discharge immunity EN61000-4-2: Grade 4, 8 kV, contact discharge B <1 %FSO test (ESD) Immunity to conducted disturbances EN61000-4-6: Grade 3, 0.15 to 80 MHz A <1 %FSO induced by radio-frequency fields 10 V, 80 % AMC (1 kHz)
ORDERING INFORMATION CTx8
E: U: bar calibration psi calibration
xxx
x
x
x
Output signal 0: 0...10 V 1: 1...6 V 4: 4...20 mA 6: 0.5...4.5 V 7: 0...5 V Fitting size D: 1/8" BSPT E: 1/4" BSPT F: 3/8" BSPT G: 1/2" BSPT K: L: M: N: P: Q: R: S: U: V: W: X: Y: 1/8" 1/4" 1/8" 1/4" G G G G G G G G
CTE8000 series 001: 0 to 1 bar N01: -1 to +1 bar P01: 0 to -1 bar 002: 0 to 2 bar 005: 0 to 5 bar 010: 0 to 10 bar 016: 0 to 16 bar 020: 0 to 20 bar 025: 0 to 25 bar 035: 0 to 35 bar 050: 0 to 50 bar 070: 0 to 70 bar 100: 0 to 100 bar
CTU8000 series 015: 0 to 15 N15: -15 to +15 P15: 0 to -15 030: 0 to 30 100: 0 to 100 200: 0 to 200 300: 0 to 300 500: 0 to 500 700: 0 to 700 1K0: 0 to 1000 1K5: 0 to 1500
psi psi psi psi psi psi psi psi psi psi psi
male, male, male, male,
brass, brass, brass, brass,
nickel nickel nickel nickel
plated plated plated plated
NPT male, brass NPT male, brass NPT male, SS 1.4305 (303) NPT male, SS 1.4305 (303) (BSP) (BSP) (BSP) (BSP) (BSP) (BSP) (BSP) (BSP) male, male, male, male, brass, brass, brass, brass, nickel nickel nickel nickel plated plated plated plated plated plated plated plated
Pressure mode G: gage pressure 1 A: absolute pressure 10
1/8" 1/4" 3/8" 1/2" 1/8" 1/4" 3/8" 1/2"
female, female, female, female,
brass, brass, brass, brass,
nickel nickel nickel nickel
G 1/8" (BSP) male, SS 1.4404 (316) no optional fitting
Note:
Other pressure ranges and options are widely available. Please contact your nearest Sensortechnics sales representative.
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. December 2008 / 508 6/6
www.sensortechnics.com


▲Up To Search▲   

 
Price & Availability of CTE8N01GD0

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X